Sun Storedge 9900 Series System

The SUN StorEdge 9980 is a multi-cabinet scalable solution which can interoperate easily with existing storage solutions. It allows massive storage expansion for the largest enterprise applications and large scale consolidation.

The StorEdge 9980 provides up to 74.7TB of raw capacity, up to 15GB/sec bandwidth, and up to 32 direct host connections (over 4000 in a SAN) supporting FC, ESCON and FICON. The primary use is data consolidation and sharing between multiple disparate open systems and mainframe hosts.

The SUN StorEdge 9990 System surpasses the performance, capacity, scalability, manageability and availability of the current product line.

The heart of the Sun StorEdge 9990 system is the Hi-Star crossbar switch, which provides levels of storage consolidation previously unattainable in the industry, and enables the virtualization of both internal and external heterogeneous storage in a single storage system. This helps to reduce TCO by enabling connections to multiple hosts, and allows for more flexibility in configuring a storage-area network (SAN) infrastructure.

The storage system is easy to operate and control and helps simplify data management. Software is available to support key storage applications typically used in data center environments, including path management, real-time replication, and remote mirroring for disaster recovery.

  9980 System

Click For Larger Image

Sun Storedge 9900 Series System

 
 
Specifications Storage Data Sheet - Click Here
 
 
  • Up to 14 36GB, 73GB or 146GB hard drives per enclosure
  • Maximum of 16.4TB capacity (base cabinet) or 65.4TB capacity (Base and 2 expansion cabinets)
  • 28 FC ports
  • 1024 volumes (Logical Device Support)
  • Scales from 2 to 28GB of Data Cache
 
 
 
Contact Us  
For more information and pricing, please contact us on :
  • +44 (0)20 7352 7007

  • Fill in our Online Contact Form - Click Here

 
 

Price List

End of life

 
 

 

 
 

Description

 

Part Numbers

 
     

Sun Storedge 9970 & 9980 Data Systems

 

 

 

SUN StorEdge 9980 Disk array frame which can contain up to 256 disk drives. AC power cable and AC power supply not included. Dimensions of frame : Height: 73.2", Width: 29.5" and Depth: 31.5"

 

T9-DKU455I-18F

 
 
 
 
 

2Gb/sec SWL fibre channel adapter that is attached to the SE9980 disk controller frame unit(DKC460I) or SE9970 integrated controller and disk array frame unit(DKC465I) and provides two 8 port fibre adapters (LC connector), 4 processors shared among 4 pairs of ports on a card, short wavelength laser diode for connection to multi-mode type fibre-optic cable for each side of the storage disk controller unit. Optical interfaces are non-OFC. Includes the hardware component required for DB Validator.

 

T9-DKC-F460I-16HSF

 
 
 

Brocade Silk Worm for StorEdge 9900

 

 

Brocade Silkworm 3900 Extended Fabrics software license; Extends all of the scalability, reliability and performance benefits of Fibre Channel SANs beyond the native 10km distance specified by the Fibre Channel standard and enables the use of full performance applications over extended distances; For use with the Brocade Silkworm 3900 switch.

SG-XSWBRO-3900EXF

 
 
 
 
 
 
 

Brocade Silkworm 3900 Remote Switch software license; Allows one logical SAN to be created that spans remote fabrics at unlimited distances; Remote Switch currently supports ATM using OC3, T-3, and T-1 speeds over extended distances; For use with the Brocade Silkworm 3900 switch.

SG-XSWBRO-3900RSW

 
   

 
 

McData Switches

 

 
 
 
 
 

McData 6140 FICON Management Software transaction key and certificate; Serial number of the McData 6140 unit and the transaction key are required to obtain license key from the web or the call-in center; FMS requires SA Services on S/390 and can only be used in FICON environments.

SG-XSWM6140-FICON

 
 
 
 
 

McData 6140 Open Systems Manager Server (OSMS) software license; Allows for inband management of the switch with 3rd party software; Runs on the McData 6140 Director.

SG-XSWM6140-OSMS

 

 

 
 

McData Options

 

 

McData Sphereon 4500 Open Systems Manager Server (OSMS) Software license; Allows for inband management of the switch with 3rd party software; Runs on the McData 4500 switch.

SG-XSWMD4500-OSMS

 
 
 

McData Sphereon 4500 Product Manager Software license; Client software required for use with EFCM-lite server software.

SG-XSWMD4500-PM

 
 

McData Sphereon 4500 8 port activation license key; This enables either 16 or 24 ports to be activated on the McData 4500 switch.

SG-XSWMD4500-UPG

 
 
 

McData FICON Management Software. Includes transaction key and software certificate. Serial number of the ED-6064 unit and the transaction key are required to obtain license key from the web or the call-in center. FMS requires SA Services on S/390 and can only be used in FICON environments.

 

SG-XSWMCD-FICON-SW

 
 
 
 
 

McData OSMS license for ED-6064. Allows for inband management of the switch with 3rd party spftware. Runs on the switch.

 

SG-XSWMCD-OSMS-SW

 
 
 

McData Enterprise Fabric Connectivity (EFC) Console, Mgmt Software & Maintenance - lite: Manages up to 12 McDATA directors/switches on a single SAN. Runs on Solaris host & enables management of all switched components from a single console.

 

SG-XSWMCD-EFCM-LT

 
   

 

 
 

FICON Adapter for StorEdge 9960

 

 

 
 
 

 

 
 

Options

 

AC Power Supply necessary when SE9970 integrated disk controller and disk array frame unit (DKC465I) is connected to single phase input. Note: Select appropriate AC power cable by region

 

T9-DKC-F465I-1PS

 

 

 
 

AC Power Supply necessary when SE9970 integrated disk controller and disk array frame unit (DKC465I) is connected to three phase input. Note: Select appropriate AC power cable by region

 

T9-DKC-F465I-3PS

 

 

 
 

AC power supply necessary when SE9980 disk array frame unit (DKU-455I) is connected to single phase input. Note: Order appropriate AC power cable by region.

 

T9-DKU-F455I-1PS

 

 

 
 

AC power supply necessary when the SE9980 disk array frame unit (DKU-455I) is connected to three phase input. Note: Order appropriate AC power cable by region.

 

T9-DKU-F455I-3PS

 

 

 
 

512MB shared memory expansion module. The shared memory is nonvolatile memory (power backed up by a battery for 7 days). Used to store cache directories and disk control information. Order in increments of 512MB from a minimum of 2GB to a maximum of 3GB(SE9980/SE9970)

 

T9-DKC-F460I-S512

 

 

 
 

Disk path expansion connectivity kit and cables required with the SE9970 integrated controller and disk array frame unit (DKC465I) when more than 64 disk drives are installed and only one ACP pair is present

 

T9-DKC-F465I-FSW

 

 

 
 

Disk path expansion connectivity kit and cables required when two Array Control Processor (ACP) pairs are used with the SE9970 integrated controller and disk array frame (DKC465I)

 

T9-DKC-F465I-FSW2

 

 

 
 

This model is attached to the SE9980 disk controller frame unit (DKC455I) or SE9970 integrated controller and disk array frame unit (DKC465I) and provides two 4 port ESCON compatible adapters for each side of the storage disk controller unit.

 

T9-DKC-F460I-8S

 

 

 
 

This FICON 1Gb/sec adapter is attached to the SE9980 disk controller frame unit (DKC460I) or SE9970 integrated controller and disk array frame unit (DKC465I) and provides S/390 Mainframe connectivity through two Fibre Channel 4-port adapters with short wavelength laser diode connected to multi-mode type fibre-optic cable for each side of the storage disk controller unit. Communication protocol is Fibre Channel Standard (under FC-SB-2). These optical interfaces are Non-OFC

 

T9-DKC-F460I-8MS

 

 

 
 

This FICON 1Gb/sec adapter is attached to the SE9980 disk controller frame unit (DKC460I) or SE9970 integrated controller and disk array frame unit (DKC465I) and provides S/390 Mainframe connectivity through two Fibre Channel 4-port adapters with long wavelength laser diode connected to single-mode type fibre-optic cable for each side of the storage disk controller unit. Communication protocol is Fibre Channel Standard (under FC-SB-2). These optical interfaces are Non-OFC

 

T9-DKC-F460I-8ML

 

 

   

Disk Options

 
 
 

 

 
 

 

 
 

One 73GB 10K RPM disk drive canister to be mounted as a spare drive in the SE9980 disk array frame (DK455I) or SE9970 integrated controller and disk array frame (DKC465I)

 

T9-DKU-F455I-72J1

 

 

 
 

Four 73GB 10K RPM disk drive canisters to be mounted as an array group in the SE9980 disk array frame (DK455I) or SE9970 integrated controller and disk array frame (DKC465I)

 

T9-DKU-F455I-72J4

 

 

 
 

One 146GB 10K RPM disk drive canister to be mounted as a spare drive in the SE9980 disk array frame (DK455I) or SE9970 integrated controller and disk array frame (DKC465I).

 

T9-DKU-F455I-146J1

 

 

 
 

Four 146GB 10K RPM disk drive canisters to be mounted as an array group in the SE9980 disk array frame (DK455I) or SE9970 integrated controller and disk array frame (DKC465I).

 

T9-DKU-F455I-146J4

 

 

   

License Key Options

 

License key and software certificate for SE9900 TrueCopy Basic software, 1 TB configuration. (SE9980/SE9970)

 

T9-044-200001-01A

 

 

 
 

License key and software certificate for SE9900 TrueCopy Basic software, 2 to 6TB configurations. License is ordered in 1TB increments up to a total of 6TBs. (SE9980/SE9970)

 

T9-044-200002-01B

 

 

 
 

License key and software certificate for SE9900 TrueCopy Basic software, 7 to 15TB configurations. License is ordered in 1TB increments up to a total of 15TBs. (SE9980/SE9970)

 

T9-044-200003-01C

 

 

 
 

License key and software certificate for SE9900 TrueCopy Basic software, 16 to 31TB configurations. License is ordered in 1TB increments up to a total of 31TBs. (SE9980/SE9970)

 

T9-044-200004-01D

 

 

 
 

License key and software certificate for SE9900 TrueCopy Asynchronous software, 1 TB configuration.(SE9980/SE9970)

 

T9-044-200008-01A

 

 

 
 

License key and software certificate for SE9900 TrueCopy Asynchronous software, 2-6 TB configurations. License is ordered in 1TB increments for a total of 6TBs. (SE9980/SE9970)

 

T9-044-200009-01B

 

 

 
 

License key and software certificate for SE9900 TrueCopy Asynchronous software, 7-15TB configurations. License is ordered in 1TB increments up to a total of 15TBs. (SE9980/SE9970)

 

T9-044-200010-01C

 

 

 
 

License key and software certificate for SE9900 Resource Manager-Open software, 2-6TB configurations. License is ordered in 1TB increments up to a total of 6TBs. (SE9980/SE9970)

 

T9-044-200023-01B

 

 

 
 

License key and software certificate for SE9900 Resource Manager-Open software, 7-15TB configurations. License is ordered in 1TB increments up to a total of 15TBs. (SE9980/SE9970)

 

T9-044-200024-01C

 

 

 
 

License key and software certificate for SE9900 Resource Manager-Open software, 16-31TB configurations. License is ordered in 1TB increments up to a total of 31TBs. (SE9980/SE9970)

 

T9-044-200025-01D

 

 

 
 

StorEdge 9900 Resource Manager-S/390 Environment 1st TB license configuration. (SE9980/SE9970)

 

T9-044-200029-01A

 

 

 
 

License key and software certificate for Resource Manager-S/390 Environment software, 2 to 6TB configurations. License is ordered in 1TB increments up to a total of 6TBs. (SE9980/SE9970)

 

T9-044-200030-01B

 

 

   

Sun StorEdge 9900 NAS Blade

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 1TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards); (For Sun StorEdge 9980 & 9970)

T9-044-200707-01A

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 2-6TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for each 1TB increment up to a total of 6TB; (For Sun StorEdge 9980 & 9970)

T9-044-200708-01B

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 7-15TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for each 1TB increment up to a total of 15TB; (For Sun StorEdge 9980 & 9970)

T9-044-200710-01D

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 16-31TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2 -port adapter printed circuit boards) for each 1TB increment up to a total of 31TB; (For Sun StorEdge 9980 & 9970)

T9-044-200711-01E

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 64TB-unlimited capacity frame license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for one final TB to total 64TB and all capacity points beyond; (For Sun StorEdge 9980 & 9970)

T9-044-200712-01F

 
 

Sun StorEdge(TM) 9900 NAS Blade Backup/Restore v2.0, license, media kit and documentation on CDROM; for Debian GNU/Linux 2.4.17; Pricesper SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards); (For Sun StorEdge 9980 & 9970)

T9-044-200714-01

 
 

Options

 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, base kit, no license, media kit and documentation on CDROM; for Debian GNU/Linux 2.4.17; (For Sun StorEdge 9980 & 9970). Additional Media

T9-200706-MEDIA

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, base kit, no license, media kit and documentation on CDROM; for Debian GNU/Linux 2.4.17; (For Sun StorEdge 9980 & 9970). 3 Year Additional Media

T9-200706-3MED

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 1TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards); (For Sun StorEdge 9980 & 9970). Annual Standard Support

T9-200707-1ST

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 1TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards); (For Sun StorEdge 9980 & 9970). 3 Year Premium Support

T9-200707-3ST

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 2-6TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for each 1TB increment up to a total of 6TB; (For Sun StorEdge 9980 & 9970). Annual Premium Support

T9-200708-1PR

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 2-6TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for each 1TB increment up to a total of 6TB; (For Sun StorEdge 9980 & 9970). Annual Standard Support

T9-200708-3PR

 
 

Sun StorEdge(TM) 9900 NAS Blade Manager v2.0, 2-6TB license, license key on CDROM, license certificate on paper; for Debian GNU/Linux 2.4.17; Pricesbased on raw storage capacity (TB) that will be allocated to each SE9900 NAS Blade feature (2 x NAS compatible 2-port adapter printed circuit boards) for each 1TB increment up to a total of 6TB; (For Sun StorEdge 9980 & 9970). 3 Year Standard Support

T9-200709-1PR

 

 

   

Sun StorEdge 9990 System

 
 
 

Options

 

Sun StorEdge(TM) 9990 Back End Director; 2 x disk adapter printed circuit boards (1 disk adapter pair), 8 x 2Gbps fibre channel ports, 8 x 400 MHz microprocessors; for the SE9990 integrated disk controller and array frame unit (DKC510I); (Note: a maximum of four of this feature can be installed per DKC).

TJ9DKC-F510I-400

 
 

Sun StorEdge(TM) 9990 FICON 8-Port Front End Director for Long Wavelength; 2 x 4 port channel adapter printed circuit boards with LC type optical connectors, 1-2Gbps Auto-sensing; mainframe fibre channel ports conform to the Long Wavelength (single mode); for the SE9990 integrated disk controller and array frame unit (DKC510I)).

TJ9DKC-F510I-8ML

 
 

Sun StorEdge(TM) 9990 FICON 8-Port Front End Director for Short Wavelength; 2 x 4 port channel adapter printed circuit boards with LC type optical connectors, 1-2Gbps Auto-sensing; mainframe fibre channel ports conform to the short Wavelength (multi- mode); for the SE9990 integrated disk controller and array frame unit (DKC510I)).

TJ9DKC-F510I-8MS

 
 

Sun StorEdge(TM) 9990 ESCON (Serial) 16-Port Front End Director; 2 x 8 port channel adapter printed circuit boards each equipped with 8 serial ports; for the SE9990 integrated disk controller and array frame unit (DKC510I)).

TJ9DKC-F510I-16S

 
 

Sun StorEdge 9990 Power Receptacle; for single phase 50A/250V 2Pole 3Wire installations; 1 x 50A 250V 2Pole 3Wire 1Phase Receptacle, 1 x back-box for 50A 60Hz receptacle; (two are required per SE9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I)

TJ99R53U2W

 
 

Sun StorEdge(TM) 9990 Power Cable Kit; for three Phase 30 Amp AC 200V/50Hz installations; 1 x power cable unit; (required when a three phase SE9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I) is shipped to Europe; one kit per unit).

TJ9DKC-F460I-3ECD

 
 

Sun StorEdge(TM) 9990 Power Cable Kit; for single phase 50 Amp AC 200V/50Hz installations; 1 x power cable unit; (required when a three phase SE9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I) are shipped to Europe; one kit per unit.)

TJ9DKC-F510I-1EC

 
 

Sun StorEdge(TM) 9990 AC Power Supply Box Kit; for single phase/200V 50 Amp installations; 2 x AC power supply distribution boxes; (one required per Sun StorEdge(TM) 9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I) when units are connected to single phase input).

TJ9DKC-F510I-1PS

 
 

Sun StorEdge(TM) 9990 Power Cable Kit; for single Phase 50 Amp AC 200V/60Hz installations; 1 x power cable unit; (required when a three phase SE9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I) are shipped to the USA; one kit per unit).

TJ9DKC-F510I-1UC

 
 

Sun StorEdge(TM) 9990 Additional Battery; 2 x battery boxes, 2x battery control printed circuit boards; for the SE9990 integrated disk controller and array frame unit (DKC510I) and/or disk array frame unit (DKU505I).

TJ9DKC-F510I-AB

 

 

 

 

 
 
 