Sun Microsystems Complete Product List

 

 

Call us +44 (0)207 352 7007

 

Online Contact Form - Click Here

 


XT9-SWCS-9500-DMMT

Cisco 9500 MobilMgrTempLic

ST9900 Cisco MDS 9500 Data MobilityManager (DMM) Temp License for one SSM for 180 days(temporary)  per one MDS9500           


Call us on: +44 (0)207 352 7007

XT9-SWCS-9509-DB

ST9900 Cisco 9509 Bundle

Sun StorageTek 9900 Cisco 9509 Bundle: Base MDS 9509 Chassis, 2 SF2 Supervisor Line Cards, and 2 2500 W Power Supplies. RoHS-compliant.          

Call us on: +44 (0)207 352 7007

XT9-SWCS-9509-DB-Z

ST9900 Cisco 9509 Bundle

Sun StorageTek 9900 Cisco 9509 Bundle: Base MDS 9509 Chassis, 2 SF2 Supervisor Line Cards, and 2 2500 W Power Supplies. RoHS-compliant.          

Call us on: +44 (0)207 352 7007

XT9-SWCS-9513-DB

ST9900 Cisco 9513 Chassis Bndl

Sun StorageTek 9900 Cisco 9513 Chassis Bundle Includes:  Base MDS 9513 Chassis, 2 SF2 Supervisor Line Cards, 2 Fabric Modules, and 2 6000 W Power Supplies.  RoHS-compliant.         

Call us on: +44 (0)207 352 7007

XT9-SWCS-9513-DB-Z

ST9900 Cisco 9513 Chassis Bndl

Sun StorageTek 9900 Cisco 9513 Chassis Bundle Includes:  Base MDS 9513 Chassis, 2 SF2 Supervisor Line Cards, 2 Fabric Modules, and 2 6000 W Power Supplies.  RoHS-compliant.         

Call us on: +44 (0)207 352 7007

XT9-SWCS-9530SF2-Z

Cisco Supervs LineCard-MDS95XX

Sun StorageTek 9900 Cisco Supervisor Line Cards for MDS95XX (incl. supervisor software - with chassis) ORDER 2 PER CHASSIS RoHS-compliant.          

Call us on: +44 (0)207 352 7007

XT9-SWCS-95ENT

ST9900 Cisco 95xx Entrprse Lic

Sun StorageTek 9900 Cisco 95xx Enterprise License OTIONAL - ORDER ONE PER CHASSIS            

Call us on: +44 (0)207 352 7007

XT9-SWCS-95EXT18+4

ST9900 MDS9500 18+4SExtOvIPLic

Sun StorageTek 9900 MDS9500 18+4 SAN Extn over IP License             

Call us on: +44 (0)207 352 7007

XT9-SWCS-95EXTIPS8

Cisco 95xx SAN Ext Lic IPS8

Sun StorageTek 9900 Cisco 95xx SAN Extension License for IPS8 ORDER 1 PER IPS-8 Services  Module if FCIP functionality is required.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-95FIC

Cisco 95xx MnFrm Lic OPTIONAL

Sun StorageTek 9900 Cisco 95xx Mainframe License OTIONAL - ORDER ONE PER CHASSIS            

Call us on: +44 (0)207 352 7007

XT9-SWCS-95FMS

Cisco 95xx Fab Mgr Svr OPTIONL

Sun StorageTek 9900 Cisco 95xx Fabric Manager Server OTIONAL - ORDER ONE PER CHASSIS            

Call us on: +44 (0)207 352 7007

XT9-SWCS-95SME18+4

MDS9500 18+4Media Encrypt.Lic.

Sun StorageTek 9900 MDS9500 Storage  Media Encryption package for one MPS 18/4-port for Cisco MDS 9500            

Call us on: +44 (0)207 352 7007

XT9-SWCS-95SSE

ST9900 Cisco 95xx SSE License

Sun StorageTek 9900 Cisco 95xx Storage Services Enabler (SSE) License ORDER ONE PER SSM MODULE            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-AR-Z

Cisco 9216 Pwr Cbl - Argentina

Sun StorageTek 9900. Cisco 9216 (either 9216A or 9216i) Power Cable  - Argentina. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-AU-Z

Cisco 9216 Pwr Cbl - Australia

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - Australia. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-EU-Z

Cisco 9216 Pwr Cbl - EU

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - European Union. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-IS-Z

Cisco 9216 Pwr Cbl - Israel

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - Israel. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-IT-Z

Cisco 9216 Pwr Cbl - Italy

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - Italy. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-NA-Z

Cisco 9216 PwrCbl - No Amer

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - North America. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-SA-Z

Cisco 9216 Pwr Cbl - S Africa

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - South Africa. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-SW-Z

Cisco 9216 Pwr Cbl - Switz

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - Switzerland. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CA92-UK-Z

Cisco 9216 Pwr Cbl - UK

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Power Cable  - UK. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60AU-Z

Cisco 9513 Pwr Cbl - Australia

Sun StorageTek 9900. Cisco 9513 Australia  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60CH-Z

Cisco 9513 Pwr Cbl - China

Sun StorageTek 9900.  Cisco 9513 China  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60EU-Z

Cisco 9513 PwrCbl - EU

Sun StorageTek 9900.  Cisco 9513 European Union  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60IN-Z

Cisco9513 PwrCbl-International

Sun StorageTek 9900.  Cisco 9513 International  Order 2 per chassis.  RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60IS-Z

Cisco 9513 Pwr Cbl - Israel

Sun StorageTek 9900. Cisco 9513 Israel  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60NA-Z

ST9900Cisco 9513 PwrCbl NA/Jpn

Sun StorageTek 9900 Cisco 9513 North America/Japan Order 2 per chassis. RoHS-compliant.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60SA-Z

Cisco 9513 Pwr Cbl - So Africa

Sun StorageTek 9900. Cisco 9513 South Africa  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60SW-Z

Cisco 9513 Pwr Cbl - Switz

Sun StorageTek 9900. Cisco 9513 Switzerland  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60US1Z

ST9900 Cisco 9513PwrCbl US

Sun StorageTek 9900 Cisco 9513 Power Cable United States (straight)  Order 2 per chassis; RoHS-compliant.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-CAB60US2Z

Cisco9513 Pwr Cbl-US (twst-lk)

Sun StorageTek 9900. Cisco 9513 United States (twist-lock).  Order 2 per chassis. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7AR-Z

Cisco PwrCrd 250V 2.5A C7cplr

Sun StorageTek 9900. Cisco Power Cord, 250VAC 2.5A, C7 coupler, Argentina. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7AU-Z

Cisco PwrCrd 250V 2.5A AS3112

Sun StorageTek 9900. Cisco Power Cord, 250VAC 2.5A, C7 coupler, AS 3112 plug, Australia. RoHS-compliant.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7EU-Z

Cisco PwrCrd 250V 2.5A EN50075

Sun StorageTek 9900. Cisco Power Cord, 250VAC 2.5A, C7 coupler, EN 50075 plug, EU. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7KO-Z

Cisco PwrCrd 250V 2.5A Korea

Sun StorageTek 9900. Cisco Power Cord, 250VAC 2.5A, C7 coupler, Korea. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7UK-Z

Cisco PwrCrd 250V 2.5A UK

Sun StorageTek 9900. Cisco Power Cord, 250VAC 2.5A, C7 coupler, BS 1363 plug, UK. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABC7US-Z

Cisco PwrCrd 250V 2.5A C7 - US

Sun StorageTek 9900. Cisco Power Cord, 125VAC 3A, C7 coupler, NEMA 1-15P plug, US. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABJC15-Z

Cisco 9216 JumperCable - Racks

Sun StorageTek 9900.  Cisco 9216 (either 9216A or 9216i) Jumper cable for Racks. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-CABJC19-Z

ST9900 Cisco 95xxCab Jmp Cble

Sun StorageTek 9900 Cisco 9513 Cabinet Jumper 250VAC 16A C20-C19 Conn  Order 2 per chassis. RoHS-compliant.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-CU-SFPL-Z

Cisco 1000 BASE-T COPPER SFP

Sun StorageTek 9900 Cisco 1000 BASE-T COPPER SFP. RoHS-compliant.             

Call us on: +44 (0)207 352 7007

XT9-SWCS-DSPAA2-Z

Cisco MDS 9000 Port Analyzer

Sun StorageTek 9900 Cisco MDS 9000 Port Analyzer / Adapter, Enhanced. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCS-FLD512-Z

ST9900 Cisco9500 Flash Dsk 512

Sun StorageTek 9900 Cisco MDS 9500 Sup Compact Flash Disk, 512MB (OPTIONAL ONE PER SUPERVISOR CARD). RoHS-compliant.           

Call us on: +44 (0)207 352 7007

XT9-SWCS-GEN2-UPMD

9513 Fabric Module Upgrade

Cisco MDS 9513 Fabric 2 Module upgrade. The Fabric 2 Module includes 1 Gen 2 fabric card, wrist  wrap and documentation. This module should be installed in pairs. (For the Cisco MDS 9513 Module.) RoHS-compliant.        

Call us on: +44 (0)207 352 7007

XT9-SWCS-SCR-Z

CiscoMDS9xxx Card Reader

ST9900 Smart Card Reader for Cisco MDS 9xxx family,  RoHS-5 Compliant             

Call us on: +44 (0)207 352 7007

XT9-SWCS-SC-Z

CiscoMDS9xxx Smart Card

Smart Card for Cisco MDS 9000 family, Spare, RoHS-6 Compliant             

Call us on: +44 (0)207 352 7007

XT9-SWCS-SSM-MD

Cisco L/C Bas noSFP StorSvcMod

Sun StorageTek 9900 Cisco Line Card  Base (no SFPs): Storage Services Module. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCSTRISFP-L-Z

Cisco 1Gb Enet 2Gb LW FC SFP

Sun StorageTek 9900 Cisco 1Gb Enet 2Gb Long Wave FC SFP. RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9-SWCSTRISFP-S-Z

ST9900 Cisco1GbEnet2GbSWaveSFP

Sun StorageTek 9900 Cisco 1Gb Enet 2Gb Short Wave FC FP.RoHS-compliant.            

Call us on: +44 (0)207 352 7007

XT9SWM10K-CUP

MCData I10K Lic Key

Sun StorageTek(TM) 9900 McDATA I10K  license key for the FICON Management Server. Field installable. Allows management by Mainframe Host Control Unit (CUP)          

Call us on: +44 (0)207 352 7007

XT9SWM10K-OPNTRNK

ST9900McData i10K OpenTrnkgLic

Sun StorageTek(TM) 9900 McDATA I10K  license key for Open  Trunking. Field installable. Open Trunking automatically balances  performance  throughout a network,  by monitoring traffic, optimizing flow and documenting actions.        

Call us on: +44 (0)207 352 7007

XT9SWM10K-SANAUTH

ST9900 McData i10K SANtegrity

Sun StorageTek(TM) 9900 McDATA I10K  license key for  SANtegrity Authentication. Field  installable.  SANtegrity  authentication requires each  device participating  in a storage  network proves its identity through the protocols FC-SP, iSCSI,  FC-GS, FC-SB and iFCP.      

Call us on: +44 (0)207 352 7007

XT9-SWM4500-SANT

McData SANtegrity for 4500

Sun StorageTek(TM) 9900 License key for McData Sphereon 4500 Switch that enables SANtegrity functionality This feature allows multi-level access control, advanced zoning security, and secure management zones.       

Call us on: +44 (0)207 352 7007

XT9-SWM4500-TRNK

McData Trunking for 4500

Sun StorageTek(TM) 9900 License key for McData Sphereon  4500 Switch that enables OpenTrunking functionality. This feature allows multiple ISLs to be combined into a single trunk.        

Call us on: +44 (0)207 352 7007

XT9-SWM6140-FICON

McData 6140 FICON MGMT SW

Sun StorageTek(TM) 9900 McData 6140 FICON Management Software transaction key and certificate; Serial number of the McData 6140 unit and the transaction key are required to obtain license key from the web or the call-in center; FMS requires SA Services on S/390 and can only be used in FICON environments.    

Call us on: +44 (0)207 352 7007

XT9-SWM6140-OSMS

McData 6140 OSMS SW license

Sun StorageTek(TM) 9900 McData 6140 Open Systems Manager Server (OSMS) software license; Allows for inband management of the switch with 3rd party software; Runs on the McData 6140 Director.        

Call us on: +44 (0)207 352 7007

XT9SWM6140-RKZIZ

McData 6140 RK w/0 ports Intl

Sun StorageTek(TM) 9900 McData Intrepid 6140 140-port HA base director switch with no ports in a McData Fabricenter Rack, US power; includes 1 McData 6140 director switch, Element Manager software, chassis, 2 power supplies requiring  240 volts, 2 SBARS, 2 CTPs, 2 fan modules, McData rail kit; Rack includes ethernet hub, 2 U.S. power  cords w/ IEC connectors; 2 year warranty also included. No  SFPs or  cables. Requires 4-port  module boards and EFCM software to be ordered separately.RoHS-5 compliant

Call us on: +44 (0)207 352 7007

XT9SWM6140-RKZPZ

McData 6140 RK w/0 ports US

Sun StorageTek(TM) 9900 McData Intrepid 6140 140-port HA base director switch with no ports  in a McData Fabricenter Rack, US power; includes 1 McData 6140 director switch, Element Manager software, chassis, 2 power supplies requiring  240 volts, 2 SBARS, 2 CTPs, 2 fan modules, McData rail kit; Rack includes ethernet hub, 2 U.S. power  cords w/ NEMA connectors; 2 year warranty also included. No SFPs or cables. Requires 4-port module boards and EFCM software to be ordered separately.RoHS-5 compliant

Call us on: +44 (0)207 352 7007

XT9-SWM6140-SANT

McData SANtegrity for 6140

Sun StorageTek(TM) 9900 License key for McData Intrepid 6140 Director that enables SANtegrity functionality. This feature allows multi-level access control, advanced zoning security,  and secure management zones.       

Call us on: +44 (0)207 352 7007

XT9-SWM6140-TRNK

McData Trunking for 6140

Sun StorageTek(TM) 9900 License key for McData Intrepid  6140 Director that enables OpenTrunking funtionality. This feature allows multiple ISLs to be combined into a single trunk.        

Call us on: +44 (0)207 352 7007

XT9SWM6140-ZPZ

McData 6140 w/0 ports

Sun StorageTek(TM) 9900 McData Intrepid 6140 140-port HA  base director switch with no ports: includes Element Manager software, chassis, 2 power supplies requiring 240 volts, 2 SBARS, 2 CTPs, 2 fan modules, 2 U.S. power cords for connection within a McData rack, McData rack mount kit;  2 year warranty also included. No  SFPs or, cables. Requires 4-port module boards and EFCM software to  be ordered separately.RoHS-5 compliant 

Call us on: +44 (0)207 352 7007

XT9SWMD4400-EM

ST9900 McData 4400 Element Mgr

Sun StorageTek(TM) 9900 License key for the McData 4400  sixteen-port capable fibre channel  switch that enable the element  manager functionality. Activating  this feature is necessary for EFCM management.        

Call us on: +44 (0)207 352 7007

XT9SWMD4400-SANT

ST9900 McData 4400 SANtegrity

Sun StorageTek(TM) 9900 License key for the McData 4400  sixteen-port capable fibre  channel switch that enables the  switch to use the SANtegrity  functionality.          

Call us on: +44 (0)207 352 7007

XT9SWMD4400-TRNK

ST9900 McData 4400 Trunking

Sun StorageTek(TM) 9900 License key for the McData 4400  sixteen-port capable fibre channel  switch that enables the switch to  use the Open  Trunking  functionality.          

Call us on: +44 (0)207 352 7007

XT9SWMD4400-UPGZ

ST9900 McData 4400 8-Port Upg

Sun StorageTek(TM) 9900 Eight port license key for the  McData 4400 sixteen port capable fibre channel switch. This part  number includes a transaction code  which will enable the customer to  receive a license key from a web  site. This license key activates an additional  eight ports on the  switch up to a  maximum of 16 ports. Eight shortwave SFPs are included  with this part number.RoHS-5 compliant   

Call us on: +44 (0)207 352 7007

XT9-SWMD4500-8P

McData 4500 w/8 ports active

Sun StorageTek(TM) 9900 McData Sphereon 4500 24-port with 8 ports activated; includes SAN  pilot management software, dual power supplies, dual fans, and rack mount kit for 72" Sun StorEdge rack, Sun Fire Cabinet and NGR rack; 2 year warranty also included; No SFPs or FC cables are included.      

Call us on: +44 (0)207 352 7007

XT9-SWMD4500-OSMS

McData 4500 OSMS SW License

Sun StorageTek(TM) 9900 McData Sphereon 4500 Open Systems  Manager Server (OSMS) Software license; Allows for inband management of the switch with 3rd party software; Runs on the McData 4500 switch.        

Call us on: +44 (0)207 352 7007

XT9-SWMD4500-PM

McData 4500 Product Manager SW

Sun StorageTek(TM) 9900 McData Sphereon 4500 Element Manager (aka Product Manager) Software license; Client software required for use with EFCM-lite server software.         

Call us on: +44 (0)207 352 7007

XT9-SWMD4500-UPG

McData 4500 8 port license key

Sun StorageTek(TM) 9900 McData Sphereon 4500 8 port activation license key; This enables either 16 or 24 ports to be activated on the McData 4500 switch.          

Call us on: +44 (0)207 352 7007

XT9SWMD4700-EM

ST9900 McData 4700 Element Mgr

Sun StorageTek(TM) 9900 License key for the McData 4700  thirty-two port capable fibre  channel switch that enables the  element manager functionality.  Activating this feature is  necessary for EFCM management.        

Call us on: +44 (0)207 352 7007

XT9SWMD4700-FICON

ST9900 McData 4700 FICON Upg

Sun StorageTek(TM) 9900 License key for the McData 4700  thirty-two port capable fibre  channel switch that enables FICON  capability.           

Call us on: +44 (0)207 352 7007

XT9SWMD4700-SANT

ST9900 McData 4700 SANtegrity

Sun StorageTek(TM) 9900 License key for the McData 4700  thirty-two port capable fibre  channel switch that enables the  switch to use the SANtegrity  functionality.          

Call us on: +44 (0)207 352 7007

XT9SWMD4700-TRNK

ST9900 McData 4700 Trunking

Sun StorageTek(TM) 9900 License key for the McData 4700  thirty-two port capable fibre  channel switch that enables the  switch to use the  Open Trunking  functionality.          

Call us on: +44 (0)207 352 7007

XT9SWMD4700-UPGZ

ST9900 McData 4700 8-Port Upg

Sun StorageTek(TM) 9900 Eight port license key for the  McData 4700 thirty-two port capable fibre channel switch. This part  number includes a transaction code  which will enable the customer to receive a license key from a web site. This license key activates an  additional eight ports on the switch up to a maximum of 32 ports.  Eight shortwave SFPs are included  with this part number.RoHS-5 compliant  

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8025

ST9900SANVERGNC ENT TO EFCMUPG

Sun StorageTek(TM) 9900 McDATA SANVERGENCE ENTERPRISE TO  EFCM STANDARD UPGRADE  - valid only with  current service maintenance contract.          

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8026

ST9900 EFCM STANDARD

Sun StorageTek(TM) 9900 EFCM STANDARD             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8027

ST9900 EFCM ADV.MOD - 32 PORTS

Sun StorageTek(TM) 9900 McDATA EFCM  ADV. MODULE - 32 PORTS             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8028

ST9900 EFCM ADV.MOD - 64 PORTS

Sun StorageTek(TM) 9900 McDATA EFCM  ADV. MODULE - 64 PORTS             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8029

ST9900EFCMADV. MOD -256 PORTS

Sun StorageTek(TM) 9900 McDATA EFCM  ADV. MODULE - 256 PORTS             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8030

ST9900 EFCM ADV. MOD- 512PORTS

Sun StorageTek(TM) 9900 McDATA EFCM  ADV. MODULE - 512 PORTS             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8032

ST9900 EFCM ADV SAN ROUTING

Sun StorageTek(TM) 9900 McDATA EFCM  ADVANCED SAN ROUTING             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8033

ST9900 EFCM ENT BASE

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE BASE             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8034

ST9900 EFCM ENT. BASE UPG

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE BASE UPGRADE - valid only with current service maintenance contract.           

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM8034P

ST9900 EFCM MEDIA UPG

Sun StorageTek(TM) 9900 McDATA EFCM  NON-SERIALIZED PHYSICAL  MEDIA UPGRADE  - valid only with  current  service maintenance  contract.           

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8036

ST9900 EFCM STD TO ENT UPG

Sun StorageTek(TM) 9900 McDATA EFCM  STD TO ENT UPGRADE             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8039

ST9900SANVERGNC STD TO EFCMUPG

Sun StorageTek(TM) 9900 McDATA SANVERGENCE STANDARD TO EFCM STANDARD UPGRADE - valid only with  current service maintenance contract.          

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCM-8040

ST9900 SANVEFCM TO EFCM ENTUPG

Sun StorageTek(TM) 9900 McDATA SANVERGENCE ENTERPRISE /  EFCM TO EFCM ENTERPRISE UPGRADE  - valid only with current service maintenance contract.          

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1004

ST9900 ENT. OS SW PACKAGE,4400

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-4400             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1005

ST9900 ENT. OS SW PACKAGE,4500

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-4500             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1006

ST9900 ENT. OS SW PACKAGE,4700

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-4700             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1007

ST9900 ENT. OS SW PACKAGE,6064

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-6064             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1008

ST9900 ENT. OS SW PACKAGE,6140

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-6140             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1009

ST9900 SECURITY SW Pkg,10000

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-10000             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1016

ST9900 ENT. FICON SW PKG,4700

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE FICON SW PACKAGE,ED-4700            

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1017

ST9900 ENT. FICON SW PKG,6064

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE FICON SW PACKAGE,ED-6064            

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1018

ST9900 ENT. FICON SW PKG,6140

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE FICON SW PACKAGE,ED-6140            

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1024

ST9900 OPTIMIZER SW PKG,4400

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-4400             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1025

ST9900 OPTIMIZER SW PKG,4500

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-4500             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1026

ST9900 OPTIMIZER SW PKG,4700

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-4700             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1027

ST9900 OPTIMIZER SW PKG,6064

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-6064             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1028

ST9900 OPTIMIZER SW PKG,6140

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-6140             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1029

ST9900 OPTIMIZER SW PKG,10000

Sun StorageTek(TM) 9900 McDATA EFCM  OPTIMIZER SW  PACKAGE,ED-10000             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1034

ST9900 SECURITY SW PKG,4400

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-4400             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1035

ST9900 SECURITY SW PKG,4500

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-4500             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1036

ST9900 SECURITY SW PKG,4700

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-4700             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1037

ST9900 SECURITY SW PKG,6064

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-6064             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1038

ST9900 SECURITY SW PKG,6140

Sun StorageTek(TM) 9900 McDATA EFCM  SECURITY SW  PACKAGE,ED-6140             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1042

ST9900 ENT. OS SW PKG,10000

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE OS SW  PACKAGE,ED-10000             

Call us on: +44 (0)207 352 7007

XT9SWMD-EFCMB1043

ST9900 ENT. FICON SW PKG,10000

Sun StorageTek(TM) 9900 McDATA EFCM  ENTERPRISE FICON SW PACKAGE,ED-10000            

Call us on: +44 (0)207 352 7007

XT9SWMD-LW10K4GZ

ST9900 McData 6140 4-Port FC

Sun StorageTek(TM) 9900 McDATA 6140  4-port fibre channel module (QPM) supporting 4Gb capability. Four longwave 10km SFPs are included. RoHS-5 compliant.          

Call us on: +44 (0)207 352 7007

XT9SWMD-LW4K4GZ

ST9900 McData 6140 4-Port FC

Sun StorageTek(TM) 9900 McDATA 6140  4-port fibre channel module (QPM) supporting 4Gb capability. Four longwave 4km SFPs are included. RoHS-5 compliant.          

Call us on: +44 (0)207 352 7007

XT9-SWMD-MOD-4P-2G

McData Fibre 4 Port Module

Sun StorEdge(TM) 9900 McData Fibre Port Module board with four ports. Auto-sensing capable for 2Gbps/1Gbps speeds. No small form pluggable (SFPs) tranceivers included. Is capable of supporting either long wave or short wave SFPs. (Option for McData ED-6064)       

Call us on: +44 (0)207 352 7007

XT9SWMD-MOD-4P-Z

McData Fibre 4 Port Module

Sun StorageTek(TM) 9900 McData Fibre Port Module board with four ports. Auto-sensing capable for 2Gbps/1Gbps speeds. No small form pluggable (SFPs) tranceivers included. This board is  capable of supporting either long wave or short wave SFPs. (Option for McData ED-6064 and ED-6140) RoHS-5 compliant.    

Call us on: +44 (0)207 352 7007

XT9SWMD-SW4GZ

ST9900 McData 6140 4-Port FC

Sun StorageTek(TM) 9900 McDATA 6140  4-port fibre channel module (QPM) supporting 4Gb capability. Four shortwave SFPs are included. RoHS-5 compliant.          

Call us on: +44 (0)207 352 7007

XT9SWMK-2-16LX4Z

ST9900 McData i10K 16prt Blade

Sun StorageTek(TM) 9900 McDATA I10K  blade with 16 ports at 2Gb and 4 ports at 10Gb. Sixteen longwave 2Gb SFPs and four 10Gb longwave XFPs included. RoHS-5 compliant.         

Call us on: +44 (0)207 352 7007

XT9SWMK-2-16SX4Z

ST9900 McData i10K 16prt Blade

Sun StorageTek(TM) 9900 McDATA I10K  blade with 16 ports at 2Gb and 4 ports at 10Gb. Sixteen shortwave 2Gb SFPs and four 10Gb shortwave XFPs included. RoHS-5 compliant.         

Call us on: +44 (0)207 352 7007

XT9SWMK-2-24LX2Z

ST9900 McData i10K 24prt Blade

Sun StorageTek(TM) 9900 McDATA I10K  blade with 24 ports at 2Gb and 2 ports at 10Gb. Twenty four longwave 2Gb SFPs and two 10Gb  longwave XFPs included. RoHS-5 compliant.         

Call us on: +44 (0)207 352 7007

XT9SWMK-2-24SX2Z

ST9900 McData i10K 24prt Blade

Sun StorageTek(TM) 9900 McDATA I10K  blade with 24 ports at 2Gb and 2 ports at 10Gb. Twenty four shortwave 2Gb SFPs and two 10Gb shortwave XFPs included. RoHS-5 compliant.         

Call us on: +44 (0)207 352 7007

XT9SWMK-4-32L-Z

ST9900 McDatai10KLW 32p4Gb

Sun StorageTek(TM) 9900 McDATA I10K  blade with 32 ports at  4Gb. Thirty two 4km longwave. No SFPs included. RoHS-5 compliant.           

Call us on: +44 (0)207 352 7007

XT9SWMK-4-32SZ

McDatai10KBladeSW32pts4Gb

Sun StorageTek 9900 McDATA I10K blade with 32 ports at 4Gb. Thirty two shortwave SFPs included. RoHS-5 compliant.           

Call us on: +44 (0)207 352 7007

XT9SWMK-4-32XZ

McDatai10KBladeLW32pts4Gb10Km

Sun StorageTek 9900 McDATA I10K blade with 32 ports at 4Gb. Thirty two 10km longwave SFPs included. RoHS-5 compliant.           

Call us on: +44 (0)207 352 7007

XT9SWMK-SWX-Z

ST9900 McData i10K Mod SWX

Sun StorageTek(TM) 9900 McDATA I10K  Improved Switch Module  SWX for Increasing Backplane  Bandwidth. Minimum of two modules required for  a chassis order.  RoHS-5 compliant.         

Call us on: +44 (0)207 352 7007

XT9SWMK-ZP-DZ

ST9900 McData i10K w/0 ports

Sun StorageTek(TM) 9900 McDATA I10K (256 port capable) Director-class Fibre Channel switch with no ports installed. Includes 2 Control Processors, power supplies, fan modules, and a 14U chassis. Enabled  features include Element Manager, SANtegrity Binding, Remote Fabric, and Dynamic Partitions. Two switch and two port modules also need to be ordered. Rackmounted in the McData FC-512-3 rack with power cords for domestic installation included. No blades, SFPs or cables are provided. RoHS-5 compliant.

Call us on: +44 (0)207 352 7007

XT9SWMK-ZP-IZ

ST9900 McData i10K w/0 ports

Sun StorageTek(TM) 9900 McDATA I10K (256 port capable)Director-class Fibre Channel switch with no ports installed. Includes 2 Control Processors, power supplies, fan modules, and a 14U chassis. Enabled  features include Element Manager, SANtegrity Binding, Remote Fabric, and Dynamic Partitions. Two switch and two port modules also need to be ordered. Rackmounted in the McData FC-512-3 rack with power cords for international inst. incl.  No blades, SFPs or cables are provided. RoHS-5 compliant.

Call us on: +44 (0)207 352 7007

XT9SWMK-ZPZ

ST9900 McData i10K w/0 ports

Sun StorageTek(TM) 9900 McDATA I10K  (256 port capable) Director-class Fibre Channel switch w/ no ports installed. Incl: 2 Control Processors, power supplies,fan modules, and a 14U chassis. Enabled features include Element Mgr, SANtegrity Binding, Remote Fabric, and Dynamic Partitions. Two switch and two port modules also need to be ordered. Incl. Rackmount kit supporting the McDATA 512-3 rack. Power cord for domestic install. incl. No blades/ SFPs/cables incl. RoHS-5 compliant.

Call us on: +44 (0)207 352 7007

XT9-XSWCS-18+4MOD

ST9900 Cisco 18+4Multiprotocol

Sun StorageTek 9900 MDS 9000 18-port Fibre Channel + 4 GigE ports for SAN extension over IP, Multiprotocol Services Module. RoHS-5 Compliant          

Call us on: +44 (0)207 352 7007

XTA-0.5M-SAS

0.5m, Mini, shielded,SAS cable

Sun Storage 0.5m, mini, shielded,  SAS cable; For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA-1.0M-SAS

1m, Mini, shielded, SAS cable

Sun Storage 1.0m, mini, shielded,  SAS cable; For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA-2.0M-SAS

2m, Mini, shielded, SAS cable

Sun Storage 2.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA-2500-1GBMEM

ST2500 1GB RAIDCTRL,MEMORY

Sun StorageTek(TM) 1 GB Memory Cartridge for  2500 Raid Controllers Only. RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2500-2UAC-KIT

ST2500 AC Pwr Sup./Fan Mod, 2U

Sun StorageTek(TM) 2500 2U AC Power Supply and Fan Module; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-2500-2UDC-KIT

ST2500 DC Pwr Sup./Fan Mod, 2U

Sun StorageTek(TM) 2500 2U DC Power Supply and Fan Module and 1 * DC power cable; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2500-2URK-19U

ST2500 2U Univ Rk Rail Kit

Sun StorEdge(TM) 2500 2U universal rack, adjustable depth rail kit; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2501-IOM

ST2501SAS I/O Module

Sun StorageTek(TM) 2501 SAS I/O Module;  RoHS-5             

Call us on: +44 (0)207 352 7007

XTA2501R01A1A2500

2501-2.5TB-5x500/7K-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 2500GB, 5 * 500GB 7.2Krpm SATA-II drives, 1  * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1A6000

2501-6TB-12x500/7K-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 6000GB, 12 * 500GB 7.2Krpm SATA-II drives, 1 * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1E1752

2501-1752G-12x146/15-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 1 * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1E730

2501-730GB-5x146/15K-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 730GB, 5  * 146GB 15Krpm SAS drives, 1 * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1F1500

2501-1500G-5x300/15K-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 1500GB, 5 * 300GB 15Krpm SAS drives, 1 * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1F3600

2501-3600G-12x300/15-1EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 1 * SAS I/O module,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1L3750

2501-3.75TB-5x750SATA1I/OAC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray,3750GB,  5 * 750GB 7.2Krpm SATA-II drives, 1  * SAS I/O module,  2 * redundant  AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS  host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1N5000

2501-5TB-5x1TBSATA-1IOM-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 5TB,  5 * 1TB 7.2Krpm SATA-II drives, 1  * SAS I/O module,  2 * redundant  AC power supplies and 2 * redundant cooling fans; Includes 1 * 1m SAS  host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A1Q2000

2501-2TB-5x400GB-1IOM-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 2TB,  5 * 400GB 10Krpm SAS, 1  * SAS I/O module,  2  * redundant  AC power supplies and  2 * redundant cooling fans; Includes 1 * 1m SAS  host cable; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2A2500

2501-2.5TB-5x500/7K-2EU-ACRR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 2500GB, 5  * 500GB 7.2Krpm SATA-II drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2A6000

2501-6TB-12x500/7K-2EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 6000GB, 12  * 500GB 7.2Krpm SATA-II drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2E1752

2501-1752G-12x146/15-2EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 *  1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2E730

2501-730GB-5x146/15K-2EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 730GB, 5  * 146GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 *  1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2F1500

2501-1500G-5x300/15K-2EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 1500GB, 5 * 300GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 *  1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2F3600

2501-3600G-12x300/15-2EU-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion  Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 *  1m SAS host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2L9000

2501-9TB-12x750SATA2I/OACRR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray , 9000GB, 12  * 750GB 7.2Krpm SATA-II drives, 2  * SAS I/O modules,  2 * redundant  AC  power supplies and 2 * redundant cooling fans; Includes 2 * 1m SAS  host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2N12000

2501-12TB-12x1TBSATA-2IOM-ACRR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray , 12TB, 12  * 1TB 7.2Krpm SATA-II drives, 2  * SAS I/O modules,  2 * redundant  AC power supplies and 2 * redundant cooling fans; Includes 2 * 1m SAS  host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2Q4800

2501-4.8TB-12x400GB-2IOM-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array,  Rack-Ready Expansion Tray, 4.8TB, 12  * 400GB 10Krpm SAS, 2  * SAS I/O modules, 2 * redundant  AC power supplies and 2 * redundant cooling fans; Includes 2 * 1m SAS  host cables; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA2501R01A2S5400

2501-5.4TB-12x450GB-2IOM-AC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array, Rack-Ready Expansion Tray, 5400GB, 12 * 450 GB  15Krpm SAS, 2 * SAS I/O module, 2 * redundant AC power supplies and 2  * redundant cooling fans; Includes  2 * 1m SAS host cable;RoHS-5        

Call us on: +44 (0)207 352 7007

XTA2501R01D2E1752

2501-1752G-12x146/15-2EU-DC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array, Rack-Ready Expansion Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant DC power supplies,  2 * redundant cooling fans and 2 * DC power cables; Includes 2 *  1m SAS host cables; RoHS-5      

Call us on: +44 (0)207 352 7007

XTA2501R01D2E730

2501-730GB-5x146/15K-2EU-DC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array, Rack-Ready Expansion Tray, 730GB, 5 * 146GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant DC power supplies,  2 * redundant cooling fans and 2 * DC power cables; Includes two 1m SAS host cables; RoHS-5      

Call us on: +44 (0)207 352 7007

XTA2501R01D2F1500

2501-1.5TB-5x300/15-2EU-DC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array, Rack-Ready Expansion Tray, 1500GB, 5 * 300GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant DC power supplies,  2 * redundant cooling fans and 2 * DC power cables; Includes 2 * 1m SAS host cables; RoHS-5      

Call us on: +44 (0)207 352 7007

XTA2501R01D2F3600

2501-3.6TB-12x300/15-2EU-DC-RR

Sun StorageTek(TM) 2501 SAS Expansion Array, Rack-Ready Expansion  Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 2 * SAS I/O modules,  2 * redundant DC power supplies, 2 * redundant cooling fans and 2 * DC power cables; Includes 2 * 1m SAS host cables; RoHS-5      

Call us on: +44 (0)207 352 7007

XTA-2510-CTRL-1GB

ST2510 CTRL, iSCI RAID, 1GB

Sun StorageTek(TM) 2510 iSCSI RAID Controller; 1GB cache and battery; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2510-CTRL-512M

ST2510 CTRL, iSCI RAID, 512MB

Sun StorageTek(TM) 2510 iSCSI RAID Controller;  512MB  cache and battery; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA2510R01A1A2500

2510-2.5TB-5x500SATA-1RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 2500GB, 5 * 500GB 7.2Krpm SATA drives, 1 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A1E730

2510-730GB-5x146/15K-1RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 730GB, 5 * 146GB 15Krpm SAS drives, 1 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A1F1500

2510-1.5TB-5x300/15K-1RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 1500GB, 5 * 300GB 15Krpm SAS drives, 1 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A1L3750

2510-3.75TB5x750SATA 1RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 3750GB, 5 * 750GB 7.2Krpm SATA drives, 1 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A1N5000

2510-5TB-5x1TBSATA-1RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array,  Rack-Ready Controller Tray,  5TB, 5 * 1TB 7.2Krpm SATA-II drives,   1 * 512MB cache iSCSI HW RAID  controller, 2 * redundant AC power  supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A1Q2000

2510-2TB-5x400GB-1RAID-AC-RR

Sun StorageTek(TM) 2510 iSCSI Array,  Rack-Ready Controller Tray,  2TB, 5 * 400GB 10Krpm SAS,   1 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power  supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2A6000

2510-6.0TB-12x500SATA2RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 6000GB, 12 * 500GB 7.2Krpm SATA drives, 2 * 512MB cache iSCSI HW RAID controllers, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2E1752

2510-1.7TB12x146/15K-2RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 1752GB, 12*146GB 15Krpm SAS drives, 2 * 512MB cache iSCSI HW RAID controllers, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2F3600

2510-3.6TB12x300/15K-2RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 3600GB, 12* 300GB 15Krpm SAS drives, 2 * 512MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2L9000

2510-9TB-12x750SATA-2RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 9000GB, 12*750GB 7.2Krpm SATA drives, 2 * 512MB cache iSCSI HW RAID controllers, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2N12000

2510-12TB-12x1TBSATA-2RAIDACRR

Sun StorageTek(TM) 2510 iSCSI Array,  Rack-Ready Controller Tray,  12TB, 12 * 1TB 7.2Krpm SATA-II drives,  2 * 512MB cache iSCSI HW RAID  controllers, 2 * redundant AC  power supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2Q4800

2510-4.8TB-12x400GB-2RAID-ACRR

Sun StorageTek(TM) 2510 iSCSI Array,  Rack-Ready Controller Tray,  4.8TB, 12 * 400GB 10Krpm SAS,  2 *  512MB cache iSCSI HW RAID controllers, 2 * redundant AC power  supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2510R01A2S5400

ST2510A-2*.5GB-12x450G/15KACRR

Sun StorageTek(TM) 2510 iSCSI Array, Rack-Ready Controller Tray, 5400GB, 12* 450GB 15Krpm SAS drives, 2 * 512 MB cache iSCSI HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans,  Includes Sun StorageTek(TM) Common Array Manager  software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA-2530-CTRL-1GB

ST2530 CTRL, SAS RAID, 1GB

Sun StorageTek(TM) 2530 SAS RAID Controller; 1GB cache and battery; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2530-CTRL-512M

ST2530 CTRL, SAS RAID, 512MB

Sun StorageTek(TM) 2530 SAS RAID Controller;  512MB  cache and battery; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA2530R01A1A2500

2530-2.5TB-5x500/7K-1RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 2500GB, 5 * 500GB 7.2Krpm SATA-II drives, 1 * 512MB cache SAS HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A1A6000

2530-6TB-12x500/7K-1RAID-AC-RR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 6000GB, 12 * 500GB 7.2Krpm SATA-II drives, 1 * 512MB cache SAS HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A1E1752

2530-1752G-12x146/15-1RAIDACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 1752GB, 12 * 146GB 15Krpm SAS drives,  1 *  512MB cache SAS HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A1E730

2530-730GB-5x146/15-1RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 730GB, 5 * 146GB 15Krpm SAS drives,  1 * 512MB cache SAS HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A1F1500

2530-1.5TB-5x300/15-1RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 1500GB, 5* 300GB 15Krpm SAS drives, 1 *  512MB cache SAS HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A1F3600

2530-3.6TB-12x300/15-1RAIDACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 3600GB, 12 * 300GB 15Krpm SAS drives,  1 *  512MB cache SAS HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A1L3750

2530-3.75TB-5x750SATA1RAIDACRR

Sun StorageTek(TM) 2530 SAS Array,  Rack-Ready Controller Tray, 3750GB, 5 * 750GB 7.2Krpm SATA-II drives,   1 * 512MB cache SAS HW RAID  controller, 2 * redundant AC power  supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A1N5000

2530-2.5TB-5x1TB/7K-1RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 5TB, 5 * 1TB 7.2Krpm SATA-II drives,   1 * 512MB cache SAS HW RAID controller, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A1Q2000

2530-2TB-5x400GB-1RAID-AC-RR

Sun StorageTek(TM) 2530 SAS Array,  Rack-Ready Controller Tray, 2TB, 5  * 400GB 10Krpm SAS,   1 * 512MB cache SAS HW RAID  controller, 2 * redundant AC power  supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5     

Call us on: +44 (0)207 352 7007

XTA2530R01A2A2500

2530-2.5TB-5x500/7K-2RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 2500GB, 5 * 500GB 7.2Krpm SATA-II drives, 2 * 512MB cache SAS HW RAID controllers, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A2A6000

2530-6TB-12x500/7K-2RAID-AC-RR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 6000GB, 12 * 500GB 7.2Krpm SATA-II drives, 2 * 512MB cache SAS HW RAID controllers, 2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A2E1752

2530-1752G-12x146/15-2RAIDACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 2 * 512MB cache SAS HW RAID controllers,  2 * redundant  AC power supplies, 2 * redundant cooling fans;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A2E730

2530-730G-5x146/15-2RAID-AC-RR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 730GB, 5 * 146GB 15Krpm SAS drives,  2 * 512MB cache SAS HW RAID controllers,  2 * redundant AC power supplies, 2 * redundant cooling fans;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A2F1500

2530-1.5TB-5x300/15-2RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 1500GB, 5* 300GB 15Krpm SAS drives, 2 * 512MB cache SAS HW RAID controllers,  2 * redundant AC power supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A2F3600

2530-3.6TB-12x300/15-2RAIDACRR

Sun StorageTek(TM) 2530 SAS Array, Rack-Ready Controller Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 2 * 512MB cache SAS HW RAID controllers,  2 * redundant  AC power supplies, 2 * redundant cooling fans;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2530R01A2L9000

2530-9TB-12x750SATA2RAIDAC-RR

Sun StorageTek(TM) 2530 SAS Array,  Rack-Ready Controller Tray, 9000 GB, 12 * 750GB 7.2Krpm SATA-II drives,  2 * 512MB cache SAS HW RAID  controllers, 2 * redundant AC  power supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A2N12000

2530-12TB-12x1TBSATA-2RAIDACRR

Sun StorageTek(TM) 2530 SAS Array,  Rack-Ready Controller Tray, 12TB, 12 * 1TB 7.2Krpm SATA-II drives,  2  * 512MB cache SAS HW RAID controllers, 2 * redundant AC power  supplies, 2 * redundant cooling fans; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2530R01A2Q4800

2530-4.8TB-12x400GB-2RAID-ACRR

Sun StorageTek(TM) 2530 SAS Array,  Rack-Ready Controller Tray, 4.8TB,  12 * 400GB 10Krpm SAS,  2 * 512MB cache SAS HW RAID  controllers, 2 *  redundant AC power supplies, 2 * redundant cooling  fans; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5     

Call us on: +44 (0)207 352 7007

XTA-2540-CTRL-1GB

ST2540 CTRL, FC RAID, 1GB

Sun StorageTek(TM) 2540 FC RAID Controller; 1GB cache and battery; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA-2540-CTRL-512M

ST2540 CTRL, FC RAID, 512MB

Sun StorageTek(TM) 2540 FC RAID Controller;  512MB  cache, battery and 2 * shortwave SFPs; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA2540R01A1A2500

2540-2.5TB-5x500/7K-1RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 2500GB, 5* 500GB 7.2Krpm SATA-II drives,  1 * 512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1A6000

2540-6TB-12x500/7K-1RAID-AC-RR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 6000GB, 12* 500GB 7.2Krpm SATA-II drives, 1 * 512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1E1752

2540-1752G-12x146/15-1RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 1752GB, 12* 146GB 15Krpm SAS drives,  1 *  512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans, 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1E730

2540-730GB-5x146/15-1RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 730GB,  5* 146GB 15Krpm SAS drives,  1 * 512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2  * redundant cooling fans, 2 * shortwave SFPs;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1F1500

2540-1.5TB-5x300/15-1RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 1500GB, 5* 300GB 15Krpm SAS drives, 1 *  512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans, 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1F3600

2540-3.6TB-12x300/15-1RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 3600GB, 12 * 300GB 15Krpm SAS drives,  1 *  512MB cache FC HW RAID controller,  2 * redundant AC power supplies, 2 * redundant cooling fans, 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1L3750

2540-3.75TB-5x750SATA1RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 3750GB,  5* 750GB 7.2Krpm SATA-II drives, 1 * 512MB cache FC HW RAID controller,  2 * redundant AC power  supplies, 2  * redundant cooling fans, and 2 * shortwave SFPs; Includes Sun StorageTek(TM) Common  Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage  Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A1N5000

2540-5TB-5x1TBSATA-1RAID-AC-RR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 5TB, 5*  1TB 7.2Krpm SATA-II drives,  1 * 512MB cache FC HW RAID  controller,   2 * redundant AC power supplies, 2  * redundant cooling  fans, and 2  * shortwave SFPs;  Includes Sun StorageTek(TM) Common  Array Manager software and  2 *  storage domains using Sun  StorageTek(TM) Storage  Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2540R01A1Q2000

2540-2TB-5x400GB-1RAID-AC-RR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 2TB, 5*  400GB 10Krpm SAS,  1 * 512MB cache  FC HW RAID  controller,  2 * redundant AC power supplies, 2  * redundant cooling  fans, and 2 * shortwave SFPs;  Includes Sun StorageTek(TM) Common  Array Manager software and  2 *  storage domains using Sun  StorageTek(TM) Storage  Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2540R01A2A2500

2540-2.5TB-5x500/7K-2RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 2500GB, 5* 500GB 7.2Krpm SATA-II drives,  2  * 512MB cache FC HW RAID controllers,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2A6000

2540-6TB-12x500/7K-2RAID-AC-RR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 6000GB, 12* 500GB 7.2Krpm SATA-II drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2E1752

2540-1752G-12x146/15-2RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant  AC power supplies, 2 * redundant cooling fans,  4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2E730

2540-730GB-5x146/15-2RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 730GB,  5* 146GB 15Krpm SAS drives,  2 * 512MB cache FC HW RAID controllers,   2 * redundant AC power supplies, 2 * redundant cooling fans, 4 * shortwave SFPs;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2F1500

2540-1.5TB-5x300/15-2RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 1500GB, 5* 300GB 15Krpm SAS drives,  2 * 512MB cache FC HW RAID controllers,  2 * redundant AC power supplies, 2 * redundant cooling fans, 4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2F3600

2540-3.6TB-12x300/15-2RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant  AC power supplies, 2 * redundant cooling fans,  4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2L9000

2540-9TB-12x750SATA2RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 9000GB, 12* 750GB 7.2Krpm SATA-II drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage  Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2N12000

2540-12TB-12x1TBSATA-2RAIDACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 12TB, 12* 1TB 7.2Krpm SATA-II drives,   2  * 512MB cache FC HW RAID controllers,  2 * redundant AC power supplies, 2  * redundant cooling fans, and 4 * shortwave SFPs; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage  Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA2540R01A2Q4800

2540-4.8TB-12x400GB-2RAID-ACRR

Sun StorageTek(TM) 2540 FC Array, Rack-Ready Controller Tray, 4.8TB, 12* 400GB 10Krpm SAS,   2 * 512MB cache FC HW RAID  controllers,  2 *  redundant AC  power supplies, 2  *  redundant  cooling fans, and 4 * shortwave  SFPs; Includes Sun StorageTek(TM)  Common Array Manager software and   2 * storage domains using Sun  StorageTek(TM) Storage  Domains software; RoHS-5    

Call us on: +44 (0)207 352 7007

XTA2540R01D2E1752

2540-1752G-12x146/15-2RAIDDCRR

Sun StorageTek(TM) 2540 FC Array, Rack- Ready Controller Tray, 1752GB, 12 * 146GB 15Krpm SAS drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant  DC power supplies, 2 * redundant cooling fans,  4 * shortwave SFPs and 2 * DC power cables; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5  

Call us on: +44 (0)207 352 7007

XTA2540R01D2E730

2540-730G-5x146/15-2RAID-DC-RR

Sun StorageTek(TM) 2540 FC Array, Rack- Ready Controller Tray, 730GB,  5* 146GB 15Krpm SAS drives,  2 * 512MB cache FC HW RAID controllers,   2 * redundant DC power supplies, 2 * redundant cooling fans, 4 * shortwave SFPs and 2 * DC power cables;  Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5  

Call us on: +44 (0)207 352 7007

XTA2540R01D2F1500

2540-1.5TB-5x300/15-2RAID-DCRR

Sun StorageTek(TM) 2540 FC Array, Rack- Ready Controller Tray, 1500GB, 5 * 300GB 15Krpm SAS drives,  2 * 512MB cache FC HW RAID  controllers,  2 * redundant DC power supplies, 2 * redundant cooling fans, 4 * shortwave SFPs and 2 * DC power cables; Includes Sun StorageTek(TM) Common Array Manager software and  2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5  

Call us on: +44 (0)207 352 7007

XTA2540R01D2F3600

2540-3.6TB-12x300/15-2RAIDDCRR

Sun StorageTek(TM) 2540 FC Array, Rack- Ready Controller Tray, 3600GB, 12 * 300GB 15Krpm SAS drives, 2 * 512MB cache FC HW RAID controllers,  2 * redundant  DC power supplies, 2 * redundant cooling fans,  4 * shortwave SFPs and 2 * DC power cables; Includes Sun StorageTek(TM) Common Array Manager software and 2 * storage domains using Sun StorageTek(TM) Storage Domains software; RoHS-5   

Call us on: +44 (0)207 352 7007

XTA25X0-0.5M-SAS-Z

0.5m, Mini, shielded,SAS cable

Sun StorageTek 0.5m, mini, shielded,  SAS cable; For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA25X0-1.0M-SAS-Z

1m, Mini, shielded, SAS cable

Sun StorageTek 1.0m, mini, shielded,  SAS cable; For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA25X0-2.0M-SAS-Z

2m, Mini, shielded, SAS cable

Sun StorageTek 2.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA25X0-3.0M-SAS-Z

3m, Mini, shielded, SAS cable

Sun StorageTek 3.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA25X0-6.0M-SAS-Z

6m, Mini, shielded, SAS cable

Sun StorageTek 6.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA-25X0-CTRL-BATT

ST25X0 Controller Battery

Sun StorageTek(TM) 25X0 Array Controller Battery; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA25X0-DOM16-ARY

ST25X0 16 Domain RTU Lic.

Sun StorageTek(TM)  Storage Domains software,  16 Domain RTU license for Sun StorageTek(TM) 25X0 Array; (License supports  up to 16 Storage Domains on an ST25X0 Array)          

Call us on: +44 (0)207 352 7007

XTA25X0-DOM32-ARY

ST25X0 32 Domain Lic

Sun StorageTek Storage Domains Software,32 Domain RTU license for Sun StorageTek 25X0 array.            

Call us on: +44 (0)207 352 7007

XTA25X0-DOM4-ARY

ST25X0 4 Domain RTU Lic.

Sun StorageTek(TM)  Storage Domains software,  4 Domain RTU license for Sun StorageTek(TM) 25X0 Array; (License supports  up to 4 Storage Domains on an ST25X0 Array)          

Call us on: +44 (0)207 352 7007

XTA25X0-DOM8-ARY

ST25X0 8 Domain RTU Lic.

Sun StorageTek(TM)  Storage Domains software,  8 Domain RTU license for Sun StorageTek(TM) 25X0 Array; (License supports  up to 8 Storage Domains on an ST25X0 Array)          

Call us on: +44 (0)207 352 7007

XTA25X0-DSE-ARY

ST25X0 Enh DS Lic

Sun StorageTek Enhanced Data Snapshot software, unlimited capacity RTU license for Sun StorageTek 25X0 array, up to 8 snapshots per volume.          

Call us on: +44 (0)207 352 7007

XTA25X0-DSS-ARY

ST25X0 DS RTU License

Sun StorageTek(TM) Data Snapshot software,  unlimited capacity RTU license for Sun StorageTek(TM) 25X0 Array           

Call us on: +44 (0)207 352 7007

XTA25X0-DVC-ARY

ST25X0 VC Lic

Sun StorageTek Volume Copy software  RTU license for Sun StorageTek 25X0 Array.            

Call us on: +44 (0)207 352 7007

XTA-3.0M-SAS

3m, Mini, shielded, SAS cable

Sun Storage 3.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA-4200-2UAC-KIT

J4200 AC Pwr Supply Mod

1 * Sun(TM) Storage  J4200 2U AC Power Supply Module; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-4200-2UFAN-KIT

J4200 Fan Mod, 2U

1 * Sun(TM) Storage J4200 2U Fan Module; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-4200-2URK-19-P

J4200 univ. rails; SSS promo

Sun(TM) Storage J4200 2U universal rack rail kit; RoHS-5. Serve, Store and Save PROMOTION with Qualified Sun Fire Server on Order.           

Call us on: +44 (0)207 352 7007

XTA-4200-2URK-19U

J4200 2U Univ Rk Rail Kit

Sun(TM) Storage J4200 2U universal rack rail kit; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-4200-IOM

J4200 SAS I/O module

1 * Sun(TM) Storage J4200 SAS I/O module; includes 1 * .5m SAS interconnect cable; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA4200R00A10DISK

J4200 CHASSIS-RR

Sun(TM) Storage J4200 array, Rack-Ready Chassis, No drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2 * redundant cooling fans; includes 1 * .5m SAS interconnect cable; RoHS-5         

Call us on: +44 (0)207 352 7007

XTA-4400-4UAC-KIT

J4400 AC Pwr Supply/Fan Mod

1 * Sun(TM) Storage J4400 4U AC Power Supply and Fan Module; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-4400-4URK-19U

J4400 4U Univ Rk Rail Kit

Sun(TM) Storage J4400 4U universal rack rail kit; RoHS-5             

Call us on: +44 (0)207 352 7007

XTA-4400-4URK19U-P

J4400 4U rack rail SSS promo

Sun(TM) Storage J4400 4U universal rack rail kit; RoHS-5. Serve, Store and Save PROMOTION with Qualified Sun Fire Server on Order.           

Call us on: +44 (0)207 352 7007

XTA4400A2N10S36

J4400 array, 10TB,LOG-36G

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 10x1TB 7200rpm SATA HDD, 2x18GB Logzilla Flash Accelerator, Includes 2* 0.5m  SAS cables; RoHS-5.          

Call us on: +44 (0)207 352 7007

XTA4400A2N11S18

J4400 array, 11TB,LOG-18G

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 11x1TB 7200rpm SATA HDD, 1x18GB Logzilla Flash Accelerator, Includes 2* 0.5m  SAS cables; RoHS-5.          

Call us on: +44 (0)207 352 7007

XTA4400A2N20S72

J4400 array, 20TB,LOG-72G

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 20x1TB 7200rpm SATA HDD, 4x18GB Logzilla Flash Accelerator, Includes 2* 0.5m  SAS cables; RoHS-5.          

Call us on: +44 (0)207 352 7007

XTA4400A2N22S36

J4400 array, 22TB,LOG-36G

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 22x1TB 7200rpm SATA HDD, 2x18GB Logzilla Flash Accelerator, Includes 2* 0.5m  SAS cables; RoHS-5.          

Call us on: +44 (0)207 352 7007

XTA4400A2N23S18

J4400 array,23TB,LOG-18G

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 23x1TB 7200rpm SATA HDD, 1x18GB Logzilla Flash Accelerator, Includes 2* 0.5m  SAS cables; RoHS-5.          

Call us on: +44 (0)207 352 7007

XTA-4400-IOM

J4400 SAS I/O module

1 *  Sun(TM) Storage J4400 SAS I/O module; includes 1  * .5m SAS interconnect cable; RoHS-5            

Call us on: +44 (0)207 352 7007

XTA4400R00A10DISK

J4400 CHASSIS-RR

Sun(TM) Storage J4400 array, Rack-Ready Chassis, No drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2 * redundant cooling fans; includes 1 * .5m SAS interconnect cable; RoHS-5         

Call us on: +44 (0)207 352 7007

XTA4400R00A2N12

J4400 array,12TB

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 12x1TB 7200rpm SATA HDD, Includes 2* 0.5m SAS cables; RoHS-5.           

Call us on: +44 (0)207 352 7007

XTA4400R00A2N24

J4400 array,24TB

Sun Storage J4400 SAS Array for Sun  Storage 7410 , Rack-Ready, 24x1TB 7200rpm SATA HDD, Includes 2* 0.5m SAS cables; RoHS-5.           

Call us on: +44 (0)207 352 7007

XTA4500R00A1A24TB

48x500/7K SATA HDD,1xI/O card

Sun(TM) Storage J4500 array, Rack-Ready, 24TB,  48 * 500GB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 *  redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 2m SAS interconnect cables and 1 * slide rail kit; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA4500R00A1A24T-P

J4500 Rack-Rdy 24TB SSS Promo

Sun(TM) Storage J4500 array, Rack-Ready, 24TB, 48 * 500GB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 2m SAS interconnect cables and 1 * slide rail kit; RoHS-5. Serve, Store and  Save PROMOTION with Qualified Sun Fire Server on Order.     

Call us on: +44 (0)207 352 7007

XTA4500R00A1L36TB

48x750/7K SATA HDD,1xI/O card

Sun(TM) Storage J4500 array, Rack-Ready, 36TB, 48 * 750GB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 *  redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 2m SAS interconnect cables and 1 * slide rail kit; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA4500R00A1L36T-P

J4500 Rack-Rdy 36TB SSS Promo

Sun(TM) Storage J4500 array, Rack-Ready, 36TB, 48 * 750GB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 2m SAS interconnect cables and 1 * slide rail kit; RoHS-5. Serve, Store and Save PROMOTION with Qualified Sun Fire Server on Order.     

Call us on: +44 (0)207 352 7007

XTA4500R00A1N48TB

48x1TB/7K SATA HDD,1xI/O card

Sun(TM) Storage J4500 array, Rack-Ready, 48TB,  48 * 1TB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2 * redundant cooling fans; Includes 2 * 2m SAS interconnect cables and 1 * slide rail kit; RoHS-5       

Call us on: +44 (0)207 352 7007

XTA4500R00A1N48T-P

J4500 Rack-Rdy 48TB SSS Promo

Sun(TM) Storage J4500 array, Rack-Ready, 48TB, 48 * 1TB 7.2Krpm SATA drives, 1 * SAS I/O Module, 2 * redundant AC power supplies and 2  * redundant cooling fans; Includes  2 * 2m SAS interconnect cables and  1 * slide rail kit; RoHS-5 . Serve, Store and Save PROMOTION with Qualified Sun Fire Server on Order.     

Call us on: +44 (0)207 352 7007

XTA5000-HF2-2G-Z

2-port FC HBA, 2Gb,X

Dual-port Fibre Channel HBA, PCI-X,  2Gb/s, for ST5000 NAS; 2*2M LC-LC optical cables, RoHS-6 compliant            

Call us on: +44 (0)207 352 7007

XTA5000-NC2-1G-Z

2-port 10/100/1000 NIC,X

Dual-port Gigabit Copper 10/100/1000 Network Interface Card,  for ST5000 NAS; 2*6m RJ45-RJ45 cables,  RoHS-5 compliant           

Call us on: +44 (0)207 352 7007

XTA5000-NF2-1G-Z

2-port MMF (Optical) NIC,X

Dual-port Gigabit MMF (Optical) Network Interface Card, for ST5000 NAS; 2*2M LC-LC optical cables,, RoHS-5 compliant           

Call us on: +44 (0)207 352 7007

XTA-6.0M-SAS

6m, Mini, shielded, SAS cable

Sun Storage 6.0m, mini, shielded, SAS cable;  For connection between array and host; RoHS-6           

Call us on: +44 (0)207 352 7007

XTA6000-RK2-PDUAD

SS6000 HH PDU - NA

RoHS 6, Sun Modular Storage : Sun Storage (tm) 6x40/6x80/CSM200, North American PDU for Sun Rack II 1242/1042E .  Includes 4*North American PDU with power cord and L6-30 connector.         

Call us on: +44 (0)207 352 7007

XTA6000-RK2-PDUAI

SS6000 HH PDU - INT

RoHS 6, Sun Modular Storage : Sun Storage (tm) 6x40/6x80/CSM200,International PDU for Sun Rack II 1242/1042E . Includes 4*International PDU with power cord and EIC 309 connector.         

Call us on: +44 (0)207 352 7007

XTA6000-RK2-RAIL

SS6000 42U Rack Kits

RoHS 6, Sun Modular Storage : Sun Storage (tm) 6x40/6x80/CSM200, Rack  Rail Kit for Sun Rack II 1242E . 1 * rack rail kit.  Each rail kit includes 2 rack rails, 4*screws and  installation guide.         

Call us on: +44 (0)207 352 7007

XTA61X0-CMB-DOM64T

61X0FetrTrnfSnap/VCRep64DomCb

Sun StorageTek Snap/VC/Rep/64Domain  transfer right-to-use (RTU) license key for Sun StorageTek 61X0  & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA61X0-CMBO-ARY2T

61X0 FeatuTrnsf- Snap/VC Comb

Sun StorageTek Snap/VolCopy transfer right-to-use (RTU) license  key for Sun StorageTek 61X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA61X0-CMBO-ARY3T

61X0FeturTrnsf-Snap/VC/Rep Cb

Sun StorageTek Snap/VC/Rep transfer  right-to-use (RTU) license key for  Sun StorageTek 61X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA61X0-CMBO-DOM8T

61X0FeatrTransfSnap/8Dom Cmb

Sun StorageTek Snap/8Domain transfer right-to-use (RTU) license  key for Sun StorageTek 61X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA61X0-DOM16-TFR

61X0 FeaturTranr 16 Domains

Sun StorageTek 16 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 61X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA61X0-DOM4-TFR

61X0FeatureTransfer4Domains

Sun StorageTek 4 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 61X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA61X0-DOM64-TFR

61X0 Feature Tranf 64 Domains

Sun StorageTek 64 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 61X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA61X0-DOM8-TFR

61X0Feature Transfer 8Domains

Sun StorageTek 8 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 61X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA61X0-DRS-TFR

61X0 Feature Transfer-Rep

Sun StorageTek Data Replicator transfrer  right-to-use (RTU) license key for Sun StorageTek 61X0  & FLX arrays.           

Call us on: +44 (0)207 352 7007

XTA61X0-DSS-TFR

61X0 Feature Transfer-Snap

Sun StorageTek Data Snapshot transfrer  right-to-use (RTU) license key for Sun StorageTek 61X0  & FLX arrays           

Call us on: +44 (0)207 352 7007

XTA61X0-DVC-TFR

61X0 Feature Transfer-VC

Sun StorageTek Volume Copy transfrer  right-to-use (RTU) license key for Sun StorageTek 61X0  & FLX arrays.           

Call us on: +44 (0)207 352 7007

XTA6580D12D4EN005

SS6580-8GB-1x2x5x1TB7K-NA

RoHS-5, Sun Storage 6580 system w/8GB cache Controller Module, 8 Host Ports & 5TB raw capacity. System includes:2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 8*4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks for back-up power;CAM S/W; 1*CSM200  trays w/5*1TB 7.2K/3 Gbps SATA drives. Installed in a Sun Rack II 1242E with North American PDU's & 3*rack rail kits; 3yr on-site warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580D15D4EJ019

SS6580-8GB-1x5x16x300G15K-NA

RoHS-5, Sun Storage 6580 system w/8GB cache Controller Module, 8 Host Ports & 19.2TB raw capacity. System inc.:2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 8*4Gb FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks for back-up power; CAM S/W; 4*CSM200 trays w/16*300GB 15K rpm / 4Gb FC-AL drives. Installed in a Sun Rack II 1242E w/North American PDUs & 6*rack rail kit; 3 yr onsite  warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580D15D8EJ019

6580-8GB/8Gb-1x5x16x300G15K-NA

RoHS-5, Sun Storage 6580 array w/8GB cache Controller Module, 8 Host Ports & 19.2TB raw capacity. System inc.:2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 8*8Gb FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks  for back-up power; CAM S/W; 4*CSM2  trays w/16*300GB 15K rpm/4 Gb FC-AL drives. Installed in a Sun Rack II 1242 w/NA PDUs & 6*rack rail kit; 3 yr on-site warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580I12D4EN005

SS6580-8GB-1x2x5x1TB7K-I

RoHS-5, Sun Storage 6580 system w/8GB cache Controller Module, 8 Host Ports &  5TB raw capacity. System includes:2*4GB-cache memory FC RAID Controllers; 2*redundant AC  power supplies & cooling fans; 16*FC ports for expansion trays & 8*4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks  for back-up pwr; CAM S/W; 1*CSM200  trays w/5*1TB 7.2K/3 Gbps SATA drives. Installed in a Sun Rack II 1242E w/International PDU  & 3*rack  rail kits; 3 yr on-site warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580I15D4EJ019

SS6580-8GB-1x5x16x300G15K-I

RoHS-5, Sun Storage 6580 system w/8GB cache Controller Module, 8 Host Ports & 19.2TB raw capacity. System inc.: 2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 8*4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks  for back-up pwr; CAM S/W; 4*CSM2 trays  w/16*300GB 15K rpm/4 Gb FC-AL drives. Installed in Sun Rack  II 1242E w/International PDUs & 6*rack rail kit; 3 yr on-site warranty. (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580I15D8EJ019

6580-8GB/8Gb-1x5x16x300G15K-I

RoHS-5, Sun Storage 6580 array w/8GB cache Controller Module, 8 Host Ports & 19.2TB raw capacity. Array inc.: 2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 8*8Gbps FC host ports w/shortwave SFPs; 2*batteries & 4GB flash disks  for back-up pwr; CAM S/W; 4*CSM2 trays  w/16*300GB 15K rpm/4 Gb FC-AL drives. Installed in Sun Rack  II 1242E w/International PDUs& 6*rack rail kit; 3 yr on-site warranty. (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6580R11D4EA2-08

SS6580-8GB-8HP-RR-CU

RoHS-5, Sun Storage (tm) 6580 Controller Module w/8GB cache and 8  host ports; Rack-Ready. Includes: 2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 2* batteries and 4GB flash disks for back-up power;  16*FC ports for expansion trays & 8 * FC host ports; 3 yr onsite warranty (Standard Configuration)    

Call us on: +44 (0)207 352 7007

XTA6580R11D8EA2-08

6580-8GB-8/8Gb-RR-CU

RoHS-5, Sun Storage (tm) 6580 Controller Module w/8GB cache and 8  host ports; Rack-Ready. Includes: 2*4GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 2* batteries and 4GB flash disks for back-up power; 16*FC ports for expansion trays & 8 * 8Gb/s FC host  ports; 3 yr onsite warranty (Standard Configuration)    

Call us on: +44 (0)207 352 7007

XTA65X0-CMB-DOM64T

65X0FetrTrnfSnp/VC/Rp/64DomCb

Sun StorageTek Snap/VC/Rep/64Domain  transfer right-to-use (RTU) license key for Sun StorageTek 65X0  & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA65X0-CMBO-ARY2T

65X0Feature Transfe-Snap/VCCmb

Sun StorageTek Snap/VolCopy transfer right-to-use (RTU) license  key for Sun StorageTek 65X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA65X0-CMBO-ARY3T

65X0FetreTransf-Snap/VC/RpCmb

Sun StorageTek Snap/VC/Rep transfer  right-to-use (RTU) license key for  Sun StorageTek 65X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA65X0-CMBO-DOM8T

65X0FeatrTransfSnap/8DomComb

Sun StorageTek Snap/8Domain transfer right-to-use (RTU) license  key for Sun StorageTek 65X0 & FLX arrays. No capacity limit.           

Call us on: +44 (0)207 352 7007

XTA65X0-DOM16-TFR

65X0 Featr Transf 16 Domains

Sun StorageTek 16 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 65X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA65X0-DOM4-TFR

65X0 Featr Trnsf 4 Domains

Sun StorageTek 4 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 65X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA65X0-DOM64-TFR

65X0 Featr Transf 64 Domains

Sun StorageTek 64 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 65X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA65X0-DOM8-TFR

65X0 Feature Trnsfr 8 Domains

Sun StorageTek 8 Domain  transfer right-to-use (RTU) license key for Sun StorageTek 65X0 & FLX arrays.            

Call us on: +44 (0)207 352 7007

XTA65X0-DRS-TFR

65X0 Feature Transfer-Rep

Sun StorageTek Data Replicator transfrer  right-to-use (RTU) license key for Sun StorageTek 65X0  & FLX arrays.           

Call us on: +44 (0)207 352 7007

XTA65X0-DSS-TFR

65X0 Feature Transfer-Snap

Sun StorageTek Data Snapshot transfrer  right-to-use (RTU) license key for Sun StorageTek 65X0  & FLX arrays           

Call us on: +44 (0)207 352 7007

XTA65X0-DVC-TFR

65X0 Feature Transfer-VC

Sun StorageTek Volume Copy transfrer  right-to-use (RTU) license key for Sun StorageTek 65X0  & FLX arrays.           

Call us on: +44 (0)207 352 7007

XTA6780D19Q4SN128

SS6780-16GB-1x9x16x1TB7K-NA

RoHS-5, Sun Storage 6780 system w/16GB cache Controller Module, 16 Host Ports & 128TB raw capacity. Sys inc: 2*8GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 16* 4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4*4GB flash disks for back-up pwr; CAM S/W; 8*CSM200 trays w/16*1TB 7.2K rpm/3 Gb SATA drives. Installed in a Sun Rack II 1242E with North American PDUs & 10*rack rail kit; 3yr onsite  warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6780D19Q4SP057

SS6780-16GB-1x9x16x450G15K-NA

RoHS-5, Sun Storage 6780 sys w/16GB cache Controller Module, 16 Host Ports & 57.6TB raw capacity. Sys. inc: 2*8GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 16* 4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4*4GB flash disks for back-up pwr; CAM S/W; 8*CSM2 trays w/16*450GB 15K rpm/4Gb FC-AL drives. Installed in a Sun Rack II 1242E w/North American PDUs  & 10*rack rail kits; 3 yr onsite warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6780D19Q8SN128

6780-16GB/8Gb-1x9x16x1TB7K-NA

RoHS-5,Sun Storage 6780 array w/16GB cache Controller Module, 16 Host Ports & 128TB raw capacity.            

Call us on: +44 (0)207 352 7007

XTA6780-DIMM08-UPG

SS6x80-DIMM-8GB-UPG-4GFD

Sun Storage 6x80 DIMM Upgrade Kit -  Includes 8 X 1 GB DIMMs cache upgrade with 8GB (2 X 4 GB) flash drives           

Call us on: +44 (0)207 352 7007

XTA6780HIC-D4F-UPG

SS6x80-HIC-UPG-8HP-4GFC

Sun Storage 6x80 Host Interface Card Upgrade Kit - Includes 2*4Gb/s  FC Host Interface Cards with 8 total Host Ports           

Call us on: +44 (0)207 352 7007

XTA6780HIC-D8F-UPG

SS6x80-HIC-UPG-8HP-8GFC

Sun Storage 6x80 Host Interface Card Upgrade Kit - Includes 2*8Gb/s  FC Host Interface Cards with 8 total Host Ports           

Call us on: +44 (0)207 352 7007

XTA6780I19Q4SN128

SS6780-16GB-1x9x16x1TB7K-I

RoHS-5, Sun Storage 6780 system w/16GB cache Controller Module, 16 Host Ports & 128TB raw capacity. Sys inc: 2*8GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 16* 4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4*4GB flash disks for back-up pwr; CAM S/W; 8*CSM200 trays w/16*1TB 7.2K rpm/ 3Gb FC-AL drives. Installed in a Sun Rack II 1242E w/ International PDUs & 10*rack rail kit; 3yr onsite  warranty. (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6780I19Q4SP057

SS6780-16GB-1x9x16x450G15K-I

RoHS-5, Sun Storage 6780 system w/16GB cache Controller Module, 16 Host Ports & 57.6GB raw capacity. Sys inc:2*8GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 16* 4Gbps FC host ports w/shortwave SFPs; 2*batteries & 4*4GB flash disks for back-up pwr; CAM S/W; 8*CSM200 trays  w/16*450GB 15K rpm/4 Gb FC-AL drives. Installed in a Sun Rack II 1242E w/International PDUs & 10*rack rail kit; 3yr onsite  warranty (Standard Configuration)

Call us on: +44 (0)207 352 7007

XTA6780I19Q8SN128

6780-16GB/8Gb-1x9x16x1TB7K-I

RoHS-5, Sun Storage 6780 Array w/16GB cache Controller Module, 16 Host Ports & 128TB raw capacity. Array inc: 2*8GB-cache memory FC RAID Controllers; 2*redundant AC power supplies & cooling fans; 16*FC ports for expansion trays & 16*8Gbps FC host ports w/shortwave SFPs; 2*batteries & 4*4GB flash disks for back-up pwr; CAM S/W; 8*CSM2 trays  w/16*1TB 7.2K rpm/3 Gb FC-AL drives. Installed in a Sun  Rack II 1242E with International PDUs & 10*rack rail kit; 3 yr on-site warranty. (Standard Config)

Call us on: +44 (0)207 352 7007

 
 
  ©2009 Business Systems International Ltd,
BSI House, 59 Markham Street, London SW3 3NR United Kingdom | Tel: +(44)20 7352 7007